F-D
Modular Direct Fired Heaters
- Air Volume: 1,000 - 19,000
- Maximum SP: 4" wg. @ standard air density
CONTROLS AND CONTROL OPTIONS
DRAWINGS
OPERATION & INSTALLATION MANUALS
- Comprehensive Supply Fan Information »
- Blower Reorientation »
- Operation and Installation Manual (PDF) »
- Operation & Installation Manual - MUA Controls (PDF) »
- Operation & Installation Manual for Recirculating Heaters (PDF) »
ADDITIONAL INFORMATION
- Accessories »
- Center of Mass Calculator »
- Direct Drive Option »
- Modular Packaged Unit Information »
- DX Coil Specifications »
- Formulas »
- Frequently Asked Heater Questions »
- Gas Manifold Diagrams »
- Heater Video »
- Motor Information »
- Performance Data »
- Request Product Information »
WRITTEN SPECIFICATIONS
DESCRIPTION
Standard features include intermittent spark ignition system with timed safety lockout, and redundant gas valves. Units consist of a galvanized enclosure with an elevated gas burner which burns directly in the air stream. The burner consists of non-clogging, stainless steel combustion baffles attached to a aluminum gas supply section. The burner is capable of nearly 100% thermal efficiency with a maximum turndown ratio of 30 to 1. The products of combustion mix with the make-up air which is introduced into the heater intake directly from outside the building. The burner module has a standard horizontal inlet and discharge duct connection and is located upstream of the blower module. The blower module has a standard horizontal inlet designed to accommodate an outside air inlet hood with standard 2" filters and screen.
To satisfy a variety of installation requirements, packages are available in a number of configurations which include additions of either a v-bank or an evaporative cooler intake module. All modules bolt together to form a rigid common base structure that mounts onto a single curb structure.
Combination packages that include both exhaust and supply fans mounted on a single roof curb are also available, please contact your sales representative for more information.
FEATURES & BENEFITS
- G90 galvanized construction
- Easy access doors
- Lifting points
- Pre-wired, pre-piped controls
- Horizontal or down discharge
- Vibration isolation
- High efficiency motors
- Adjustable drive sheaves
- Fully insulated casing
- Stainless steel burner
- 120 volt control transformer with single point electrical connection
- Redundant gas valves
- Intermittent spark pilot with timed safety lockout
- Electronic flame modulation
- High temperature limit switch
- Airflow proving switch
- Economizer inlet thermostat
- Motor starter
- Disconnect switch
- Burner observation port
OPTIONS
- Electrical Cabinet LED Lights
- Propane Fuel Application
- Room Override Thermostat
- Motorized Intake Damper
- Remote control panel including summer/winter switch and operating lights
- Freeze Stat with Bypass Timer
- Hi/Low Gas Pressure Switches
- Room Modulating Thermostat
- High Gas Pressure Regulator
- Convenience Outlet
- DX Cooling Coils
- Evaporative Cooler Intake
- V-Bank Filter Intake
- Sloped Filter Intake
- Auxiliary Starters
- Inlet Gas Pressure Gauge
- Indoor Hanging Cradle
- VAV Packages
- Roof Curbs
- Clogged Filter Switch
- Cooling Thermostat and Interlock
- Extra Set of V-Belts
- DDC Control capability for BACnet MS/TP, LonWorks, Johnson N2, and Modbus Protocol
- Z83.18 Recirculating Configuration
CERTIFICATIONS
The FD Model has been certified by ITS. This certification mark indicates that the product has been tested to and has met the minimum requirements of a widely recognized (consensus) U.S. and Canadian products safety standard, that the manufacturing site has been audited, and that the applicant has agreed to a program of periodic factory follow-up inspections to verify continued performance. |
|
Model FD is ETL Listed under file number 103371695COL-001 and complies with ANSI Z83.4-Second Edition and CSA 3.7-2006 Standards. Recirculating Model FD is ETL listed under file number 3035352-002 and complies with ANSI Z83.18 Standard – Fourth Edition. This product may be covered by one or more of the following patent number(s): (United States) 6629523, or other U.S. and foreign patents pending. |